Telephone cables GERDA-TP, GERDA-ST, GERDA-TS

Telephone cables GERDA-TP, GERDA-ST, GERDA-TS

default alt
  • Affordable prices, no markups or overpayments;
  • Stability of production and rhythm of deliveries;
  • We comply with GOSTs and all technological standards.

To find out the cost of the cable, send the order code to our managers.

Generate order code

Delivery is carried out as soon as possible after the order is placed.

Telephone cables GERDA-TP, special telephone cables GERDA-ST,
telephone exchange cables GERDA-TS TU 27.32.13-040-76960731-2016

  • Telephone cables with insulation and a sheath made of polymer materials, designed for operation in networks with a nominal remote power supply voltage of up to 225 and 145V AC at 50 Hz or a voltage of up to 315 and 200V DC, respectively.

    The cables are classified into telephone cables GERDA-TP, special telephone cables GERDA-ST, and telephone exchange cables GERDA-TS.


Scope of application

  • GERDA-TP telephone cables and GERDA-ST special telephone cables are designed for use in local primary communication networks. GERDA-ST cables have enhanced protection against external electromagnetic interference. GERDA-TP and GERDA-ST comply with GOST 31943-2012.

  • GERDA-TS telephone exchange cables are designed for the installation of low-frequency exchange equipment in telephone stations.

    The primary application area is shown in Table 7.


Cable construction

  • The nominal diameter of copper conductors (see Table 2): 0.32 mm; 0.4 mm; 0.5 mm; 0.64 mm; 0.7 mm.

    In GERDA-TP telephone cables, the conductor insulation can be (optional, see Table 3):

    • Polyethylene “P”,
    • Foam-skin polyethylene “pp”,
    • Cross-linked polyethylene “Ps”,
    • Silicone rubber “R”.

    The conductor insulation of GERDA-ST cables is made of polyethylene “P”.

    The conductor insulation of GERDA-TS exchange cables is made of the following materials:

    • PVC “V”,
    • Polyethylene “P”,
    • Cross-linked polyethylene “Ps”,
    • Thermoplastic elastomer “T”.

    Insulated conductors, distinctly different in insulation color, are twisted into pairs (triples).

    Cables with up to 100 pairs (triples) can be twisted using either a layer twist method or a bundle twist method.

    In the layer twist method, all pairs (triples) may have:

    • Individual color coding (see Table 5);
    • One counting pair and one guiding pair with colors different from all other pairs in the twist and from each other;
    • Digital marking.
  • In the bundle twist method, the cable core with up to 100 pairs (triples) consists of groups (elementary bundles of 5 or 10 pairs) with distinguishing colored binding threads (see Table 6). In cables with more than 100 pairs, the core is twisted from main bundles consisting of 50 or 100 pair bundles.

    By agreement with the customer, the core center may contain 2 signal conductors (for cables with 10 to 100 pairs) or 4 signal conductors (for cables with 100 or more pairs). Cables designed for installation in high-humidity conditions are manufactured with water-blocking tapes “v” or a hydrophobic filler “Z”.

    Cables with the “FR” index are fire-resistant, with conductor insulation made of silicone rubber. These cables maintain functionality for at least 180 minutes under open flame exposure and temperatures of +750°C (PO1 according to GOST 31565-2012). GERDA-TP and GERDA-TS cables have a common shield made of aluminum-polymer tape with a tinned drain wire. The sheath of cables labeled with the material “P” is made of polyethylene, while cables with the index “ng(A)-HF” are made of halogen-free polymer compositions.

    Cables labeled with the material “V” have a sheath made of PVC compounds, with the index “ng(A)” indicating low flammability PVC, and “ng(A)-LS” indicating low fire hazard with reduced smoke and gas emission. Cables labeled with the material “T” have a sheath made of thermoplastic elastomers, offering an extended operating temperature range from -50°C to +125°C. Special GERDA-ST cables have an aluminum sheath “A” providing protection against increased electromagnetic interference. The sheath of cables designed for suspension on communication line supports is applied simultaneously to the cable core and the steel strand, which acts as a supporting element.

    Cables may have armor made of galvanized steel wires or galvanized steel tapes, with external protective coverings compliant with GOST 7006.


Special indicators

Cables that are subject to increased requirements for external influencing factors can be manufactured in the following versions:

  • “T” — heat-resistant (up to +200°C, for material “T”);
    “HL” — frost-resistant;
    “EHL” — resistant to extremely cold conditions, cable installation down to -40°C;
    “UV” — UV-resistant;
    “H” — resistant to acids, alkalis, and environments with high hydrogen sulfide content;
    “M” — oil and fuel-resistant;
    “ZG” — sheath resistant to rodents, ants, and termites;
    “DV60” — service life of at least 60 years.


Designation for ordering

Type of product
Ttelephone
STspecial telephone
TStelephone exchange

Conductor insulation material
Ppolyethylene (if the index ng(A)-HF is present – halogen-free polymer composition)
ppfoam-skin polyethylene
Pscross-linked polyolefin
VPVC compound
Tthermoplastic elastomer
Rsilicone rubber

Cable sheath material without armor or inner sheath for armored cable
Ppolyethylene (if the index “HF” is present – halogen-free polymer composition)
PPanti-corrosion layer and polyethylene
VPVC compound
Tthermoplastic elastomer
Aaluminum

Overall shield is present in all cables, but for some types, it does not need to be explicitly indicated – see Table 3
no shield designation
epmade of aluminum-polymer tape

Water penetration protection
none
Zhydrophobic filling
vwater-blocking tape

Integrated cable messenger
no messenger
twith integrated steel messenger

Armor
no armor
Btape armor with outer protective covering
BGtape armor without outer protective covering
BbGtape armor, interlocked, without outer protective covering
Bbarmor with galvanized steel tapes
Kbarmor with galvanized steel wires

Protective hose for armored cable
no protective hose
ShPUV-stabilized polyethylene
ShVPVC compound
PUV-stabilized polyethylene

Fire safety rating
ng(A)
ng(A)-LS
ng(A)-HF
ng(A)-FRLS
ng(A)-FRHF

Number of structural elements see Table 2

Structural element
2pair
3triple

Conductor diameter, mm
0.32, 0.4, 0.5, 0.64, 0.7

Special characteristics
no special characteristic
HLenhanced frost resistance of cables
EHLresistance to extreme cold conditions
UVUV-resistant
Moil and gasoline-resistant design
Hresistant to chemically aggressive environments
Tenhanced heat resistance
ZGresistant to damage by rodents, ants, termites
DV60cable service life of at least 60 years

Operating voltage
not specified for TS cable
200up to 200V DC
315up to 315V DC

GERDA –

T

Ps

P

ep

Bb

Shp

ng(A)

20

x

2

x

0.5

HL

315

Example of cable designation when orderingDescription
GERDA-TPsPepBbShpng(A)-HF 20x2x0.5 EHL–315
TU 27.32.13-040-76960731-2016
Telephone cable for local primary communication networks with a nominal voltage of 315V, with 20 pairs of single-wire copper conductors with a diameter of 0.5 mm, insulated with cross-linked polyolefin, with a common screen made of aluminum-polymer tape, armored with steel tapes without a cushion, with a protective sheath made of a halogen-free polymer composition, resistant to extreme cold conditions
GERDA-TPPepT 100x2x0.32–200
TU 27.32.13-040-76960731-2016
Telephone cable for local primary communication networks with a nominal voltage of 200V, with 100 pairs of single-wire copper conductors with a diameter of 0.32 mm, with polyethylene insulation, with a common screen made of aluminum-polymer tape, in a polyethylene sheath, with an integrated steel cable
GERDA-TSVng(A) 103x2x0.5
TU 27.32.13-040-76960731-2016
Telephone exchange cable for mounting low-frequency exchange equipment, with 103 pairs of single-wire copper conductors with a diameter of 0.5 mm, insulated with PVC compound, with a common screen made of aluminum-polymer tape, in a low-flammability PVC sheath

Table 1. Technical specifications

CharacteristicsParameters
Operating temperaturefrom −70° to +200°C (see Table 4)
Minimum cable installation temperaturenot below −40°C for cables with the “EHL” index
not below −30°C for cables with the “HL” index
not below −10°C for cables with a polyethylene sheath and hydrophobic filling
not below −15°C for other cable types
Operating voltageup to 145V and 225V AC at 50 Hz
up to 200V and 315V DC
Electrical insulation resistance during operation, t = +20°Cat least 6500 MΩ·km for cables with polyethylene insulation without hydrophobic filler
at least 5000 MΩ·km for cables with polyethylene insulation with hydrophobic filler
at least 6500 MΩ·km for cables with cross-linked polyolefin insulation
at least 100 MΩ·km for cables with silicone rubber insulation
at least 50 MΩ·km for cables with halogen-free polymer composite insulation
at least 50 MΩ·km for cables with thermoplastic elastomer insulation
at least 10 MΩ·km for cables with PVC insulation
Electrical resistance of conductive cores during operation, t = +20°C216 (± 13) Ω for conductive cores with a diameter of 0.32 mm
139 (± 9) Ω for conductive cores with a diameter of 0.4 mm
90 (+ 5.9 ÷ −6.0) Ω for conductive cores with a diameter of 0.5 mm
55 (± 3) Ω for conductive cores with a diameter of 0.64 mm
45 (± 3) Ω for conductive cores with a diameter of 0.7 mm
Operating capacitance, recalculated per 1 km length at a frequency of 0.8 or 1.0 kHznot more than 50 nF for cables with polyethylene insulation without hydrophobic filler
not more than 55 nF for cables with polyethylene insulation with hydrophobic filler
not more than 70 nF for cables with cross-linked polyolefin insulation
not more than 85 nF for cables with silicone rubber insulation
not more than 140 nF for cables with halogen-free polymer composite insulation
not more than 140 nF for cables with thermoplastic elastomer insulation
not more than 140 nF for cables with PVC insulation
Climatic performanceperformance “UHL”, “TS”, “T” placement category 1, 2, 4 (according to GOST 15150-69). Cables can be used in all macroclimatic regions, including tropical areas.
Fire resistance (for “FR” cables)at least 180 minutes under open flame exposure and a temperature of at least +750°C (PO1 according to GOST 31565-2012)
Resistance to longitudinal moisture spread in case of outer sheath damagemoisture is completely blocked in the design with a water-blocking element and hydrophobic filling
Mold resistancecables are resistant to mold exposure, with a biological contamination rating of up to 2 points
Permissible bending radii for installation and operationFor non-armored cables: at least 10 diameters for plastic sheaths and 15 diameters for aluminum sheaths.
For armored cables: at least 12 diameters for plastic sheaths and 20 diameters for aluminum sheaths.
Service life, at least60 years for “DV60” cables,
30 years for GERDA-ST cables,
20 years for cables with silicone rubber insulation,
25 years for other cables

Table 2. Nominal conductor diameter, number of pairs, triples

Cable nameConstruction elementNominal conductor diameter, mmNumber of construction elements: pairs (“x2”), triples (“x3”)
GERDA-TP telephone cablePair (“x2”)0.32; 0.40; 0.50; 0.64; 0.72×2; 5×2; 10×2; 20×2; 30×2; 50×2; 100×2; 150×2; 200×2; 300×2; 400×2; 500×2; 600×2
GERDA-ST special telephone cablePair (“x2”)0.5010×2; 20×2; 30×2; 50×2; 100×2; 200×2
GERDA-TS telephone exchange cablePair (“x2”)0.32; 0.40; 0.505×2; 10×2; 16×2; 20×2; 30×2; 41×2; 103×2
Triple (“x3”)5×3; 10×3; 20×3

Table 3. Cable brand and design features

Cable brandCable nameDesign features
GERDA-TPPeptelephone cable with polyethylene insulation, in a polyethylene sheath, shielded
GERDA-TPPepZwith hydrophobic filler
GERDA-TPPepvwith water-blocking tape
GERDA-TPPepBbShpin tape armor, in a polyethylene protective hose
GERDA-TPPepKbShpin wire armor, in a polyethylene protective hose
GERDA-TPPepZBbShpwith hydrophobic filler, in tape armor, in a polyethylene protective hose
GERDA-TPPepvBbShpwith water-blocking tape, in tape armor, in a polyethylene protective hose
GERDA-TPPepZKbShpwith hydrophobic filler, in wire armor, in a polyethylene protective hose
GERDA-TPPepvKbShpwith water-blocking tape, in wire armor, in a polyethylene protective hose
GERDA-TPPeptwith built-in cable
GERDA-TPppZPtelephone cable with foam-skin polyethylene insulation, in a polyethylene sheath, shieldedwith hydrophobic filler
GERDA-TPppvPwith water-blocking tape
GERDA-TPPepBtelephone cable with polyethylene insulation, in a polyethylene sheath, shieldedin tape armor, with an external protective covering
GERDA-TPPepZBwith hydrophobic filler, in tape armor, with an external protective covering
GERDA-TPPepvBwith water-blocking tape, in tape armor, with an external protective covering
GERDA-TPPepBGin tape armor, without an external protective covering
GERDA-TPPepBbGin tape armor, applied in a “lock”, without an external protective covering
GERDA-TPPepvBGwith water-blocking tape, in tape armor, without an external protective covering
GERDA-TPsPeptelephone cable with cross-linked polyolefin insulation, in a polyethylene sheath, shielded
GERDA-TPsPepZwith hydrophobic filler
GERDA-TPsPepvwith water-blocking tape
GERDA-TPsPepBbShpin tape armor, in a polyethylene protective hose
GERDA-TPsPepKbShpin wire armor, in a polyethylene protective hose
GERDA-TPsPepZBbShpwith hydrophobic filler, in tape armor, in a polyethylene protective hose
GERDA-TPsPepvBbShpwith a water-blocking tape, in wire armor, in a polyethylene protective hose
GERDA-TPsPepZKbShpwith hydrophobic filler, in wire armor, in a polyethylene protective hose
GERDA-TPsPepvKbShpwith a water-blocking tape, in tape armor, in a polyethylene protective hose
GERDA-TPsPeptwith an integrated cable
GERDA-TPsPepng(A)-HFtelephone cable with cross-linked polyolefin insulation, in a halogen-free polymer composite sheath, shielded
GERDA-TPsPepvng(A)-HFwith a water-blocking tape
GERDA-TPsPepBbShpng(A)-HFin tape armor, in a polyethylene protective hose
GERDA-TPsPepKbShpng(A)-HFin wire armor, in a polyethylene protective hose
GERDA-TPsPepvBbShpng(A)-HFwith a water-blocking tape, in tape armor, in a polyethylene protective hose
GERDA-TPsPepvKbShpng(A)-HFwith a water-blocking tape, in wire armor, in a polyethylene protective hose
GERDA-TPVtelephone cable with polyethylene insulation, in a PVC sheath, shielded
GERDA-TPVBGin tape armor, without an external protective covering
GERDA-TPVBbShvin tape armor, in a PVC protective hose
GERDA-TPVKbShvin wire armor, in a PVC protective hose
GERDA-TPVng(A)telephone cable with polyethylene insulation, in a low-combustibility PVC sheath, shielded
GERDA-TPVBbShvng(A)in tape armor, in a PVC protective hose
GERDA-TPVKbShvng(A)in wire armor, in a PVC protective hose
GERDA-TPVng(A)-LStelephone cable with polyethylene insulation, in a PVC sheath with reduced fire hazard and low smoke and gas emissions, shielded
GERDA-TPVBBShvng(A)-LSin tape armor, in a protective PVC hose
GERDA-TPVKBShvng(A)-LSin wire armor, in a protective PVC hose
GERDA-TRVng(A)-FRLStelephone cable with silicone rubber insulation, in a low fire hazard PVC sheath with low smoke and gas emission, shielded, fire-resistant
GERDA-TRVBBShvng(A)-FRLSin tape armor, in a protective PVC hose
GERDA-TRVKBShvng(A)-FRLSin wire armor, in a protective PVC hose
GERDA-TRPng(A)-FRHFtelephone cable with silicone rubber insulation, in a halogen-free polymer composite sheath, shielded, fire-resistant
GERDA-TRPBBShpng(A)-FRHFin tape armor, in a polyethylene protective hose
GERDA-TRPKBShpng(A)-FRHFin wire armor, in a polyethylene protective hose
GERDA-STPAPPspecial telephone cable with polyethylene insulation, in aluminum and polyethylene sheaths
GERDA-STPAPPBin tape armor, with an outer protective cover
GERDA-STPAPPBGin tape armor, without an outer protective cover
GERDA-STPAPBPin tape armor, with an outer polyethylene protective hose
GERDA-STPAVspecial telephone cable with polyethylene insulation, in aluminum and PVC sheaths
GERDA-TSVstation telephone cable with PVC plastic insulation and sheath, shielded
GERDA-TSVng(A)station telephone cable with PVC plastic insulation, with a low-flammability PVC plastic sheath, shielded
GERDA-TSVng(A)-LSstation telephone cable with low fire hazard PVC plastic insulation and sheath, with low smoke and gas emission, shielded
GERDA-TSPng(A)-HFstation telephone cable with insulation and sheath made of halogen-free polymer composites, shielded
GERDA-TSPsng(A)-LSstation telephone cable with cross-linked polyolefin insulation, with low fire hazard PVC plastic sheath and low smoke and gas emission, shielded
GERDA-TSPsng(A)-HFstation telephone cable with cross-linked polyolefin insulation, with a halogen-free polymer composite sheath, shielded
GERDA-TSTng(A)station telephone cable with thermoplastic elastomer insulation and sheath, shielded

Table 4. Fire safety rating and operating temperature depending on the sheath material

Sheath materialFire safety ratingSheath material descriptionOperating temperature of the cable, °C
P(without index)Polyethylene sheath (for cable without hydrophobic filler)-50°…+60°C
Polyethylene sheath (for cable with hydrophobic filler)-50°…+50°C
ng(A)-HFSheath made of polymer compositions that do not spread combustion in group installation and do not emit corrosive gaseous products during burning and smoldering-50°…+70°C
ng(A)-FRHFSame, fire-resistant cable-50°…+70°C
ng(A)-HF HLSheath made of polymer compositions that do not spread combustion in group installation and do not emit corrosive gaseous products during burning and smoldering, cold-resistant version-60°…+70°C
ng(A)-HF EHLSheath made of polymer compositions that do not spread combustion in group installation and do not emit corrosive gaseous products during burning and smoldering, extreme cold-resistant version, installation down to -40°C-70°…+70°C
V(without index)Sheath made of PVC plastics-50°…+70°C
ng(A)Sheath made of low-combustibility PVC plastics-50°…+70°C
ng(A) HLSheath made of low-combustibility PVC plastics, cold-resistant version-60°…+70°C
ng(A)-LSCables that do not spread combustion in group installation, with reduced smoke and gas emission-50°…+70°C
ng(A)-FRLSSame, fire-resistant cable-50°…+70°C
Tng(A)Insulation and sheath made of flame-retardant thermoplastic elastomers-50°…+125°C (for T version)
-50°…+200°C (for T-T version)

Table 5. Color coding of conductor insulation in elementary bundle or core

Pair (Triple) reference number in elementary bundleDesignation and color of conductor
abc
1
2
3
4
5
WhiteBlue
Orange
Green
Brown
Gray
Turquoise
6
7
8
9
10
RedBlue
Orange
Green
Brown
Gray

Table 6. Color coding of elementary bundles in 100-pair cables or main bundles

Nominal number in the elementary bundleColor of binding elementsNominal number in the elementary bundleColor of binding elements
1Blue6White
2Orange7Red
3Green8Black
4Brown9Yellow
5Gray10Purple

Table 7. Preferred application areas of cables (considering section 3.1 of GOST 31943-2012)

Cable brandCable namePreferred application area
GERDA-TPPepTelephone cable with solid polyethylene insulation, aluminum-polymer tape screen, in a polyethylene sheathFor installation in telephone ducts, collectors, shafts, along building walls, and for suspension on overhead communication lines
GERDA-TPPepZSame, with hydrophobic fillingSame, and in high humidity conditions
GERDA-TPPepvSame, with a water-blocking tape instead of hydrophobic filling
GERDA-TPppZPTelephone cable with foam-skin polyethylene insulation, hydrophobic filling, in a polyethylene sheath, shielded
GERDA-TPppvPSame, with a water-blocking tape
GERDA-TPPepBTelephone cable with solid polyethylene insulation, aluminum-polymer tape screen, in a polyethylene sheath, armored with steel tapes, with an external protective coveringFor installation in all types of soil that are not highly corrosive to steel armor and not subject to frost heaving
GERDA-TPPepZBSame, with hydrophobic fillingSame, and in high humidity conditions
GERDA-TPPepBGTelephone cable with solid polyethylene insulation, aluminum-polymer tape screen, in a polyethylene sheath, armored with galvanized steel tapesFor installation in collectors, tunnels, and shafts
GERDA-TPPepBbgSame, with armor applied in a “lock” formation
GERDA-TPPepBbpShpTelephone cable with solid polyethylene insulation of conductors, with an aluminum-polymer tape screen, in a polyethylene sheath, armored with galvanized steel tapes, with an outer protective polyethylene hoseFor laying in soils of all categories (except mechanized laying in rocky soils), not subject to permafrost deformations
GERDA-TPPepZBbpShpSame, with hydrophobic fillingSame, and in high humidity conditions
GERDA-TPPepvBbpShpSame, but instead of hydrophobic filling, a water-blocking tape is used
GERDA-TPPepKbShpTelephone cable with solid polyethylene insulation of conductors, with an aluminum-polymer tape screen, in a polyethylene sheath, armored with galvanized steel wires, with an outer protective polyethylene hose. Increased resistance to tensile forcesFor laying in soils of all categories (except mechanized laying in rocky soils), not subject to permafrost deformations
GERDA-TPPepZKbShpSame, with hydrophobic fillingSame, and in high humidity conditions
GERDA-TPPepvKbShpSame, but instead of hydrophobic filling, a water-blocking tape is used
GERDA-TPPeptTelephone cable with solid polyethylene insulation of conductors, with an aluminum-polymer tape screen, in a polyethylene sheath, with an integrated support wireFor suspension on poles
GERDA-TPVTelephone cable with solid polyethylene insulation of conductors, with an aluminum-polymer tape screen, in a sheath made of polyvinyl chloride (PVC) plasticFor single installation along interior walls of buildings and inside premises
GERDA-TPVng(A)-LSSame, in a sheath made of low-flammability PVC plastic with low smoke and gas emissionSame, and for bundle installation (group installation)
GERDA-TPsPepng(A)-HFTelephone cable with cross-linked polyolefin insulation, in a halogen-free polymer composition sheath, shielded
GERDA-TPVBbShvng(A)-LSTelephone cable with solid polyethylene core insulation, with an aluminum-polymer tape screen, in a low-flammability PVC plastic sheath with low smoke and gas emission, armored with galvanized steel tapes, with an outer protective PVC hoseFor single and group installation indoors, in dry tunnels
GERDA-TPsPepBbShpng(A)-HFTelephone cable with cross-linked polyolefin core insulation, with an aluminum-polymer tape screen, in a halogen-free polymer composition sheath, armored with galvanized steel tapes, with an outer protective polyethylene hose
GERDA-TPVKbShvng(A)-LSTelephone cable with solid polyethylene core insulation, with an aluminum-polymer tape screen, in a low-flammability PVC plastic sheath with low smoke and gas emission, armored with galvanized steel wires, with an outer protective PVC hose. Increased resistance to tensile forcesSame, and when installing cable with a large slope or on vertical sections
GERDA-TPsPepKbShpng(A)-HFTelephone cable with cross-linked polyolefin core insulation, with an aluminum-polymer tape screen, in a low-flammability PVC plastic sheath with low smoke and gas emission, armored with galvanized steel wires, with an outer protective polyethylene hose. Increased resistance to tensile forces
GERDA-TPVBGTelephone cable with solid polyethylene core insulation, with an aluminum-polymer tape or aluminum tape screen, in a PVC plastic sheath, armored with galvanized steel tapesFor indoor installation, in dry tunnels
GERDA-STPAPPSpecial telephone cable with solid polyethylene core insulation, in aluminum and polyethylene sheathsFor installation in ducts, collectors, and soils of all categories (except mechanized – in rocky soils), not subject to frost heave, if the cable is not exposed to high tensile forces, in conditions characterized by increased electromagnetic influence
GERDA-STPAPPBGSame, armored with two steel tapes, with anti-corrosion coatingFor installation in collectors, tunnels, in conditions characterized by increased electromagnetic influence
GERDA-STPAPBPSpecial telephone cable with solid polyethylene core insulation, in aluminum and polyethylene sheaths, armored with two steel tapes, with an outer protective polyethylene hoseFor soils of all categories (except mechanized – in rocky soils), not subject to frost heave, in conditions characterized by increased electromagnetic influence
GERDA-STPAVSpecial telephone cable with solid polyethylene core insulation, aluminum, and PVC sheathsFor installation in collectors, tunnels, in conditions characterized by increased electromagnetic influence, indoors, and along building walls
GERDA-TRV…ng(A)-FRLSTelephone cable with silicone rubber insulation, in a low-hazard PVC plastic sheath with low smoke and gas emission, with an aluminum-polymer tape screen, fire-resistantFor installation in fire protection systems, as well as other systems that must remain operational in fire conditions
GERDA-TRP…ng(A)-FRHFTelephone cable with silicone rubber insulation, in a halogen-free polymer composite sheath, with an aluminum-polymer tape screen, fire-resistant
GERDA-TSVStation telephone cable with PVC plastic insulation and sheath, shieldedFor single installation in industrial premises
GERDA-TSVng(A)-LSStation telephone cable with low-hazard PVC plastic insulation and sheath, with low smoke and gas emission, shieldedFor installation (including group installation), considering the combustible load of cables, inside buildings and structures
GERDA-TSPsng(A)-LSStation telephone cable with cross-linked polyolefin insulation, with a low-hazard PVC plastic sheath and low smoke and gas emission, shielded
GERDA-TSPng(A)-HFStation telephone cable with halogen-free polymer composite insulation and sheath, shieldedFor installation (including group installation), considering the combustible load of cables, inside buildings and structures with a high concentration of people, including multifunctional high-rise buildings and building complexes
GERDA-TSPsng(A)-HFStation telephone cable with cross-linked polyolefin insulation, with a halogen-free polymer composite sheath, shielded

Выберите свой город
Выберите язык
RU UA FR EU OT RU RU UA FR EU OT RU