Power cables for airfield lighting equipment

Power cables for airfield lighting equipment

default alt
  • Affordable prices, no markups or overpayments;
  • Stability of production and rhythm of deliveries;
  • We comply with GOSTs and all technological standards.

To find out the cost of the cable, send the order code to our managers.

Generate order code

Delivery is carried out as soon as possible after the order is placed.

KUSIL-PsE (TU 3543-033-76960731-2016)

High-voltage

  • KUSIL-PsE (TU 3543-033-76960731-2016) High-voltage High-voltage cables 5kV and 6kV are used to create a cable ring for airfield lights (signs), connecting to the brightness regulator and the primary winding of isolating transformers.

    KUSIL-PsE (TU 3543-033-76960731-2016)
    KUSIL-PsEP 1x6mk – 5
    • do not propagate combustion
    • operating temperature: –60°…+80°C (up to +90°C for extended periods)
    • class 2 stranded copper conductors, tinned or untinned
    • nominal conductor cross-section: 6, 8, 10 mm²
    • conductor insulation made of cross-linked polyethylene
    • minimum bending radius: 5 times the outer cable diameter
    • test voltage: 18kV / 21kV (for 5kV / 6kV cables)
    • “ZG” version – resistant to rodents, ants, and termites
    • service life of at least 30 years
    • cables resistant to:

      • solar radiation (UV), ozone,
      • water,
      • oil and gasoline,
      • weak solutions of acids and alkalis,
      • de-icing and anti-icing agents

KUIN-KuGVV-HL 2x2.5 (N) - M, KUIN-KuGVV 2x4 (N) - M (TU 3551-023-76960731-2012)

Low-voltage

  • Cables are designed for electrical installations in stationary wiring of lighting networks, as well as for mounting electrical equipment, machines, mechanisms, and tools with a nominal AC voltage of up to 500V at frequencies up to 400Hz. These cables are used to connect airfield lights and signs to the secondary windings of isolating transformers in series-powered lighting and signage circuits.

    KUIN-KuGVV-HL (TU 3551-023-76960731-2012)
    KUIN-KuGVV-HL 2×2.5 (N) – M
    • Two flexible copper conductors with a nominal cross-section of 2.5 or 4 mm², compliant with Class 5 of GOST 22483-2012.
    • Insulation made of PVC compound. Insulated conductor colors: blue and brown.
    • Conductors are twisted into a core and wrapped with a polymer film.
    • Outer sheath made of PVC compound.
    • Nominal operating voltage: 500V.
    • Operating temperature range: from -60°C to +70°C.
    • Cables are resistant to:

      • water,
      • aviation oils and fuels,
      • weak solutions of acids and alkalis,
      • de-icing chemical agents.

KUSIL-KGTP (TU 3540-025-76960731-2013)

Low-voltage

  • Flexible low-voltage power cables are used to connect airfield lights and signal signs to the secondary winding of isolating transformers.

    KUSIL-KGTP (TU 3540-025-76960731-2013)
    KUSIL-KGTP 2×4 – 660
    • Nominal AC voltage: ∼660V, frequency up to 400Hz
    • Do not propagate combustion
    • “HF” version – halogen-free cable with low smoke and gas emission
    • Operating temperature: –60°…+125°C
    • Flexible copper conductors, Class 5 or 6 (extra flexible), tinned or untinned
    • Conductor cross-sections: 1.0; 1.5; 2.5; 4.0; 6.0; 10.0 mm² and above
    • Number of conductors per cable: from 1 to 36
    • Insulation and sheath made of synthetic elastomers (rubber)
    • Test voltage: 2.5kV / 50Hz for 5 minutes
    • Minimum bending radius: 5 times the outer cable diameter
    • Cables are resistant to:

      • Multiple bends (up to 30,000 bends)
      • Solar radiation (UV)
      • Ozone
      • Water
      • Oil, gasoline, kerosene
      • Acid solutions (sulfuric, boric, formic, etc.)
      • Hydraulic fluid (SkyDrol LD-4)
      • De-icing and anti-icing agents
      • Cleaning agents, etc.

Выберите свой город
Выберите язык
RU UA FR EU OT RU RU UA FR EU OT RU