The GERDA-KOU cable is a universal optical cable designed for long-distance data transmission. It contains from 2 to 144 optical fibers and is resistant to tensile and compressive loads, as well as temperature fluctuations from -60°C to +60°C. It is suitable for installation inside buildings, in tunnels, and in open spaces. The cable can be manufactured in a non-flammable version, making it safe for use in subways and other public facilities. Its service life is at least 25 years, with a 2-year warranty.
Gerda-RGL and Gerda-SBL are elevated light systems designed for runway protection and stop bar visibility. Gerda-RGL includes alternating flashing yellow lights to warn of potential runway incursion zones. Gerda-SBL features red lights to improve visibility of stop bars during poor weather when inset lights are obscured. Both systems meet ICAO Annex 14, FAA AC 150/5345-46, and Russian FAP-381 standards. Lights are made of aluminum alloy and stainless steel, with flexible mounting and easy maintenance.
The GERDA-TFL cable is designed for telephone exchanges, base stations, data centers (DC), and uninterruptible power supplies (UPS). It ensures low inductance and electromagnetic compatibility.
Grating flooring is a system of bearing and connecting steel elements used in industrial and construction applications. The gratings are produced in standard or custom sizes, ensuring strength, high open area, and safe operation. Manufactured with precision equipment for consistent quality.
The hermetic metal hose GERDA-MG protects cables and wires from mechanical and chemical effects, moisture, and ultraviolet radiation. Suitable for concealed and open installation.
The GERDA-EL 217 high-intensity elevated airfield light is designed for use in AGL systems powered by 6.6A regulators. It complies with AP-170 and ICAO Annex 14 standards. Suitable for approach lighting, runway threshold, edge, and end lighting, the GERDA-EL 217 ensures reliable performance under harsh airfield conditions.
KVIP cables are used in industrial networks, measurement systems, and for connecting digital sensors. They are distinguished by high durability and resistance.
The DZI-3 gas detector is designed to measure hydrocarbon gas levels indoors and outdoors using a dual-channel infrared photometric method. It features a corrosion-resistant, explosion-proof housing and real-time digital readouts. The device supports periodic self-diagnostics, non-volatile memory, and service-friendly magnetic key adjustments directly in hazardous areas. Data is transmitted via analog or digital interfaces.
The KUSIL cable is used for the transmission and distribution of electrical power in networks with voltages of 0.66, 1, and 3 kV. It is applied in power circuits, control systems, lighting, and signaling. It can be installed in buildings, tunnels, underground, as well as in open air. Fire-resistant modifications are suitable for fire protection systems and emergency safety. The armored version is suitable for seismically active areas and water bodies. Special versions ensure low inductance for telephone exchanges and data centers. Its wide range of applications makes the KUSIL cable a universal solution for various facilities.
The KUSIL-KGTP cable is a flexible power cable designed for connecting mobile machines, mechanisms, and equipment to electrical networks. It is resistant to high temperatures, ultraviolet radiation, and mechanical stress. The cable's insulation and sheath are made of thermoplastic elastomers, ensuring durability and reliable operation. It is designed to operate within a wide temperature range from -60°C to +80°C and can withstand voltages up to 1000 V. Suitable for use in harsh climatic conditions and industrial facilities.
The KUSIL-O cable is a lightweight power cable designed for electricity distribution in both stationary and mobile installations. It is also used for lighting circuits in metro systems. Thanks to its lightweight construction, the cable has a lower weight compared to standard power cables. The insulation is made from low fire-hazard materials, and the conductors have digital identification. The cable operates in temperatures ranging from -60°C to +125°C and has a service life of at least 25 years.
The Lined Standpipe is designed for safe handling of aggressive chemicals such as hydrochloric, nitric, or sulfuric acids with high chlorine or fluorine content. It features seamless PTFE rotary lining, providing uniform protection inside and out. Hinges are made of titanium, special acid-resistant steel, or are PTFE-lined. This design allows using standard piping while protecting the standpipe from corrosion, and it supports both vacuum and pressure operations.
This liquid phase loading arm enables safe and sealed transfer of liquefied hydrocarbon gases to and from tank cars. Equipped with PCT swivel joints and flexible connections, it adapts to various valve configurations. Quick couplings ensure fast connection, while relief valves and hoses provide safe depressurization after operation.
The medium-voltage KUSIL cable is designed for the transmission and distribution of electrical energy in 10, 20, and 35 kV networks with a grounded or isolated neutral. It complies with the international standard IEC 60502-2 and is intended for stationary installation under various conditions: in the ground, water, cable structures, ducts, and industrial premises, including damp and flood-prone areas. Cables with the "UF" designation are resistant to solar radiation and can be used outdoors. They are also suitable for explosive zones in accordance with GOST R IEC 60079-14-2008.
The OSN-EM modular rack is designed for safe and convenient access to tank trucks and other service areas. It features quick on-site assembly, non-slip surfaces, optional loading risers, safety systems, and can be manufactured from carbon, galvanized, or stainless steel according to international safety standards.
The lock secures the pipe in working position during loading to neutralize reactive jet forces. It includes a lever mounted on hinge.