GERDA-RY brightness regulator

GERDA-RY brightness regulator

default alt
  • Affordable prices, no markups or overpayments;
  • Stability of production and rhythm of deliveries;
  • We comply with GOSTs and all technological standards.

To find out the cost of the cable, send the order code to our managers.

Generate order code

Delivery is carried out as soon as possible after the order is placed.



Purpose

  • Brightness regulators (GERDA-RY) with a rated power of 2.5 / 5 / 10 / 15 / 20 / 25 / 30 kVA are designed to stabilize and regulate current in cable loops of airfield lighting systems with series circuit configurations.

  • The GERDA-RY regulators utilize modern electronic components predominantly of domestic production.


Main parameters and specifications

    • current regulation is based on the principle of thyristor phase control;
    • the output current circuit provides galvanic isolation using an air-cooled transformer;
    • the regulator’s multiprocessor control system ensures control, measurement, and stabilization of the output current according to the selected brightness step;
    • use of standard current tables for brightness step regulation, as well as user-defined current tables stored in the non-volatile memory of the control unit;
    • continuous insulation monitoring of the cable loop;
    • retention of the last selected setting in the regulator’s memory in case of power outage or remote control system failure;
    • data display on a four-line alphanumeric LCD screen;
    • current system: 6.6 A;
    • capability of setting up to 8 brightness steps;
    • overcurrent and overvoltage protection with current loop blocking and alarm signaling;
    • burned lamp monitoring system;
    • remote and local control options;
    • remote control capability via a single RS-485 communication line using MODBUS protocol;
    • convenient access to replaceable components, modules, and instruments for efficient maintenance and repair;
    • all important information regarding regulator operation, the number of burned lamps, and insulation status is displayed on the control panel;
    • data input, settings, and calibration of the regulator are performed using control buttons on the control panel;
    • automatic disconnection of the power transformer primary winding upon activation of any protection system;
    • operating time tracking of the CCR (Constant Current Regulator);
    • four casters on the bottom of the regulator facilitate its movement;
    • degree of protection – IP 31 according to GOST 14254-2015.

Technical specifications

Parameter NameParameter Value
Rated input AC voltage, V380
Permissible deviation of input voltage from nominal, %+10 / -15
Input voltage frequency, Hz50
Rated output current, A6.6
Output current stabilization accuracy:
– at rated current value, not worse than, %
– at values below nominal, %
under deviations of:
– supply voltage within –15% to +10%;
– supply frequency within ±2.5%;
– load within 50% to 100%
±2
±3
Number of brightness steps, not less than3…8
Current settling time at each step, max, sec2
Overcurrent protection threshold, A:
– for rated output current of 6.6 A
6.95
Output power, kVA2.5; 5; 10; 15; 20; 25; 30
Minimum efficiency, %95
Overvoltage protection response time after load circuit disconnection, max, sec2
Grounding system (protective grounding) for 3NPE 50 Hz 230/400 V with automatic disconnection from power sourceTN-C-S