Checking the optical line after installation: attenuation, reflectometer and typical defects
Checking the optical line after installation: attenuation, reflectometer and typical defects

Table of Contents OLTS and OTDR: Two Different Instruments End-to-End Attenuation Measurement How to Read a Reflectogram Typical Defects Table: Defect — Manifestation — Detection — Action Preparing the Line…

How to check the power cable after installation: insulation, integrity, connections and protocol
How to check the power cable after installation: insulation, integrity, connections and protocol

Table of Contents Testing Sequence Visual Inspection Checking Conductor Integrity and Phase Identification Insulation Resistance Measurement Checking Connections, Joints, and Lugs Additional Tests by Voltage Class Test Table Actions for…

Grounding the shield and cable armor: schematics, when needed, and typical errors
Grounding the shield and cable armor: schematics, when needed, and typical errors

Table of Contents Why Shields and Armor Are Grounded: Different Functions Single-Point and Two-Point Shield Grounding Grounding Schemes in Words Table: Line Type, What Is Grounded, Scheme, Risk Shield Grounding…

Why the power cable is heating up: overload, poor contact, cross-section and laying conditions
Why the power cable is heating up: overload, poor contact, cross-section and laying conditions

Table of Contents Normal Heating and Emergency Overheating Main Causes of Overheating Table: Where It Heats Up and What to Check Diagnostic Sequence Why a Cable Heats Up at a…

Which UTP cable to choose for PoE and IP cameras: category, copper, AWG and line length
Which UTP cable to choose for PoE and IP cameras: category, copper, AWG and line length

Contents Short answer: what matters more than the category PoE standards and camera power Cat5e or Cat6 for IP cameras Copper Cu vs CCA AWG23 vs AWG24 Effect of line…

How to check UTP cable after installation: tester, breakage, mixed pairs and line quality
How to check UTP cable after installation: tester, breakage, mixed pairs and line quality

Table of Contents What to check immediately after installation Checking with a simple LAN tester Typical faults and their symptoms Table of tester results and causes Checking the quality of…

UTP 305m bay: how to calculate cable consumption and how many lines will be obtained
UTP 305m bay: how to calculate cable consumption and how many lines will be obtained

Table of Contents Why a coil is exactly 305 meters Formula for calculating cable consumption What reserve to allow for installation Calculation examples for different lines Table: how many lines…

Crimp UTP cable and pinout RJ45: T568A, T568B and check connection
Crimp UTP cable and pinout RJ45: T568A, T568B and check connection

Table of Contents What is the difference between T568A and T568B RJ45 pinout table by colors When the same scheme is needed on both ends Is a crossover cable needed…

Fire-resistant cable line: cable, fasteners and penetration as a single system
Fire-resistant cable line: cable, fasteners and penetration as a single system

Table of Contents What a Fire-Resistant Cable Line Is What Elements the System Consists Of Why Choosing Only an FR Cable Is Not Enough The Role of Fasteners and Supporting…

Group laying of cables: how does the permissible current load change?
Group laying of cables: how does the permissible current load change?

Table of Contents Why the Current Load Is Reduced What the Coefficient Depends On How to Choose the Coefficient Correctly Calculation Example Grouped Laying in Tray, Duct and Ground Typical…